설명
Wind Speed Direction Sensor 3 Wind Cups S Type IP64 Waterproof Integrated Anemometer for Environment 9V‑30V
Item Type: Wind Speed Direction Sensor
Material: ABS, Aluminum Alloy
Size: Approx. 458 x 232mm / 18 x 9.1in
Gross Weight: Approx. 1575g/3.5lb
Measuring Object: Wind Speed, Wind Direction
Signal Output: RS485 for Modbus Protocol
Measuring Range: Wind Speed 0-70m/s
Cable Length: Approx. 5.2m/17.1ft
Accuracy: Wind Speed: ±(0.3+0.03V)m/s (V represents real time wind speed value), Wind Direction: ±3°
Resolution: Wind Speed: 0.1m/s, Wind Direction: 1°
Start Wind Speed: ≤0.5m/s
Maximum Power Consumption: 0.9W
Load Capacity: DC12V Power Supply, Current Output Impedance ≤350Ω; DC24V Power Supply, Current Output Impedance ≤900Ω
Operating Environment: Temperature: -35°C-60°C
Humidity: ≤100%RH Non Condensing
Guard Level: IP64
Widely Used: Meteorology, Marine, Environmental, Airport, Port, Laboratory, Industry, Agriculture, Traffic, etc.
4 Installation Methods:
1. Horizontal bottom mounting, wind direction must face upward
2. Horizontal top mounting, wind direction must face upward
3. Vertical side mounting, wind direction must face upward
4. Pole mounting, wind direction must face upward
Wire Connection Method:
Red Wire: Power Positive Pole
Black Wire: A+
Yellow Wire: B-
Green Wire: Power Negative Pole
Standard for ModBus RTU Communicate Protocol:
Serial Port Format: 8 data bits, 1 stop bit, no parity, default baud rate 9600bps, serial debugging software set to hex send and receive, minimum interval between two comms at least 500ms, CRC in the manual is the parity, 2 bytes. Default device address is 1.
for Modbus CRC Check Steps:
1. The preset 16 bit register is hexadecimal FFFF, is called CRC register;
2. The first 8 bit data is different from the lower part of the CRC register or put the result in the CRC register;
3. Move the contents of the register to the right one bit (towards the low), fill the highest bit with 0, and check the lowest bit;
4. If the lowest position is 0: repeat step 3 (shifting again) If the lowest position is 1: the CRC register is XOR with polynomial A001 (1010 0000 0000 0001);
5. Repeat steps 3 and 4 until you move to the right 8 times, so that the entire 8 bit data has been processed;
6. Repeat Step 2 to Step 5 to process the another 8 bit data.
The resulting CRC register is the CRC code (the resulting CRC code is low before high after).
Troubleshooting:
1. Wind blade rotation is not great, hysteresis is large. Due to long term use, there are foreign bodies or stuck in the bearing.
2. When analog signal or RS232, RS485 output, the instrument display value is incorrect. The correct data cannot be obtained because the cable connection is faulty or the comm serial port is faulty. Check whether the cable connection is correct and secure, whether the serial port is occupied, and whether the serial port settings are correct.
-
Fruugo ID:
409346138-866948018
-
EAN:
5061330898021