TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

₩29,890
무료 배송

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • 브랜드: Unbranded

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • 브랜드: Unbranded
희망소매가격: ₩38,890
가격: ₩29,890
절약 금액: ₩9,000 (23%)
판매자::
₩29,890
무료 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Feature: 1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy. 2. The module has no display function and the data is read through the TTL interface. 3. Support for Modbus-RTU standard protocol, including host computer software. 4. Comes with TTL to USB data cable and external CT. 5. The module works for Windows operating systems. Specification: Item Type: Communication Module Measurement Range: AC 80-260V Resolution: 0.1 V Accuracy:0.5% 2. Current: Measurement Range:0-100A Resolution: 0.001 A Accuracy: 0.5% 3. Active Power Measurement Range:0-2.3 KW Min. Measuring Power: 0.4W Resolution: 0.1W 4. Power Factor Measurement Range: 0.00-1.00 Resolution: 0.01 Accuracy:1% 5. Frequency Range:45 Hz-65 Hz Resolution: 0.1 Hz Accuracy: 0.5% 6. Active Electrical Energy Metering Range:0-9999.99 kWh Resolution: 1Wh Accuracy: 0.5% Communication Protocol: 1. Physical layer protocol: Physical layer adopts UART to TTL communication interface Baud rate:9600,8 bit data bit,1 bit stop bit, no check 2. Application layer protocol The application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero). The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721. The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations. 3. Read the results of the measurement The command format for the host to read the result of the measurement is (8 bytes in total): Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte. Reply of slave computer to the following command format is divided into two types: Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte. Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte. The exception code is read as follows (the same below): 0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error. The register layout of the measured results is shown in the following table: v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Register address Description Resolution 0x000 Voltage value measurement 1LSB corresponds to 0.1V 0x001 Current Measurement Value Low 16 Bits 1LSB corresponds to 0.01A 0x0002 Current Measurement Value High 16 Bits 0x0003 Power Measurement Value Low 16 Bits 1LSB corresponds to 0.1W 0x0004 Power Measurement Value High 16 Bits 0x0005 Energy Measurement Value Low 16 Bits 1LSB corresponds to 1Wh 0x0006 Energy Measurement Value High 16 Bits 0x0007 Frequency Measurement Value 1LSB corresponds to 0.1Hz 0x0008 Power Factor Measurement Value 1LSB corresponds to 0.01 0x0009 Alarm State 0xFFFF alarm,0x0000 no alarm 4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine 5. Zero power 6. Calibration 7. CRC check Package List: 1 x Module1 x Data Cable1 x CT1 x User Manual Note: The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
  • Fruugo ID: 413522675-873947086
  • EAN: 7603816554106

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Warning: Please read the product instructions carefully before use to ensure correct use.
일련번호: 7603816554106

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 금 17 10월 2025–금 24 10월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795