TG30S 220-440V AC Mini 3-Phase Sequence Relay Protector Voltage Phase Protective Relay Z7ZXT

₩35,490
무료 배송

TG30S 220-440V AC Mini 3-Phase Sequence Relay Protector Voltage Phase Protective Relay Z7ZXT

  • 브랜드: Unbranded

TG30S 220-440V AC Mini 3-Phase Sequence Relay Protector Voltage Phase Protective Relay Z7ZXT

  • 브랜드: Unbranded
희망소매가격: ₩53,390
가격: ₩35,490
절약 금액: ₩17,900 (33%)
판매자::
₩35,490
무료 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Features Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority. Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light. Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release. The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W. Feature: Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority. Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light. Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority. Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release. The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W. There is no requirement for motor wiring when used for motor protection. This product complies with GB/T 14048.1-2000, GB14048.5-2001 eqv IEC60947-1:1999. The EMC of this product complies with the measurement method and permissible value of radio interference characteristics of GB4343-1995. Three-phase voltage imbalance protection, static phase loss protection, reverse phase protection, lightning protection, and surge resistance. Specification: Model: TG30S Voltage: 220-440V AC Meet the standard: GB/T 14048.1-2000, GB14048.5-2001 eqv IEC60947-1:199 Package list: 1 * Phase Sequence Protector Note: The actual product color may deviate from the photo due to light. There may be a slight deviation in the measurement of product. Working status: 1. L1, L2, L3 three-phase wiring is correct, the monitor green light is on, the relay is closed; if the Package List
  • Fruugo ID: 397215007-847505331
  • EAN: 9789622307919

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.
재료: As shown in the figure

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 금 10 10월 2025–목 16 10월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기