설명
Item Type:Relay Module_x000D_
Product Model: YF-11_x000D_
Input Voltage:DC7~24V_x000D_
Output Power: Can Control DC Power Load within 10A_x000D_
Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable_x000D_
Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch_x000D_
Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc._x000D_
P-21: Give the signal, after a delay of A second, the output starts_x000D_
P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops_x000D_
P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops_x000D_
P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops._x000D_
P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second_x000D_
P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second._x000D_
P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal)_x000D_
P-28: After power on, after a delay of A second, the output starts until the power is off_x000D_
P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops_x000D_
P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop_x000D_
P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop_x000D_
P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds_x000D_
P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds_x000D_
P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped._x000D_
P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within A+B time_x000D_
P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops_x000D_
P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time_x000D_
P-42: The signal disappears, after a delay of time A, the output starts; working time B ends_x000D_
P-43: The signal disappears. After the time A exceeds, the output starts; the working time B ends_x000D_
P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop._x000D_
P-45: No action when energized, after signal is given; output starts A time, stops B time; cycle C times and automatically stops; Give signal again, execute again_x000D_
P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off_x000D_
P-47: After giving the signal more than A times, the output starts and stops for B seconds_x000D_
P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds_x000D_
3. Description of button setting:_x000D_
Power on display "" means entering standby state;_x000D_
Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function_x000D_
Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)_x000D_
Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)_x000D_
Press K1 for the fourth time, the display "" means entering the standby state_x000D_
Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode_x000D_
4. The decimal point time unit description:_x000D_
X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds_x000D_
XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds_x000D_
XXX has no decimal point, timing range: 1 second to 999 seconds_x000D_
XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
-
Fruugo ID:
314565398-701223214
-
EAN:
3851969966695