Lithium Battery Active Balancer RV Energy Storage BMS Battery Equalizer with Connection Cable 4-24S
Item Type: Active Battery Equalizer
Material: PC
Balance Method: Energy transfer (whole group synchronization)
Battery Type: Support for ternary, lithium iron phosphate battery
Start Condition: The first 4 strings cannot be lower than 12V
Start Differential Pressure: None
Stop Condition: The working voltage cannot be higher than 10V
Balance Current: Voltage difference 0.1V, current 1.2A, maximum 10A
Power Supply Mode: Battery powered by itself (the first 4 strings)
Low Voltage Protection: Shutdown (1S lower than 2.5V, first 4S lower than 10V)
Temperature Protection: Shutdown at 50℃, resume work at 45℃
Working Power Consumption: Maximum 0.2W
Static Power Consumption: 0.01W
Bluetooth Communication: Communication is not supported
Sleep Switch: (Off) to work continuously, (On) to sleep after 8 hours of work
Sleep Activation: Sleep state, automatically activated when charging and discharging
Balanced Series: The same model supports
Balanced Parallel: Support
Balance Value: 0-0.05V
Wire Requirements: Silicone wire above 0.5 square (as short as possible)
Note:
1. This model cannot remove the connector to balance other batteries. For example, after balancing a drum pad, move it to another drum pad. If you do this, you will definitely damage the balancer and must be fastened together with the battery.
2. If you want e this balancer as a solar battery, your balance current may not be large. Since the solar battery is always charging and discharging, the battery voltage difference is small and the current obtained is also small. If the capacity is the same, the greater the voltage difference, the greater the current.
3. The pressure difference of the new battery will not be too large, but the capacity should be consistent. If the battery voltage difference is 0.2-0.3V, the voltage difference is too large. At the end of full charge and discharge, there may be a voltage difference of 0.5V, and the balance current at this time will also be the largest. But the value of the differential pressure does not last long.
4. Balance Current of about 10A: When the voltage difference exceeds 0.8V, the balance current of 10A will be reached, but this does not mean that each battery chain can reach the current of 10A.
Generally, 4A balanced current is the safest. Keeping the balance current at 10A for a long time will damage the balancer.
Do not create more than 0.7v differential pressure and keep it for 10 minutes or longer will damage the balancer.
First Time Using:
1. Be careful to connect each balance line, wrong wiring will damage the balancer.
2. Do not disassemble the connector port every time. Frequent connection and disconnection of connectors can cause poor contact and affect the balance current.
3. The battery must be installed and fixed.
4. The green connector must be pulled out before wiring.
5. After the balance line is connected, you can insert the connector, and start charging for the first time to enhance the balance effect.
-