LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

₩3,532,090
무료 배송

LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

  • 브랜드: Unbranded

LCD Digital Audiometer Professional Adult Hearing Screening Instrument Pure Tone Audiometer for Hearing Test with Response Switch Handle 100240V EU Pl

  • 브랜드: Unbranded
희망소매가격: ₩4,591,690
가격: ₩3,532,090
절약 금액: ₩1,059,600 (23%)
판매자::
₩3,532,090
무료 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Feature:1. HIGH ACCURACY: Pure tone audiometer offers continuous attenuation with a step size of 5dB, ensuring a precision of less than 1dB.2. ADVANCED TECHNOLOGY: Utilizing advanced technology and algorithms, it accurately identifies and measures sounds within different frequency ranges, providing accurate hearing evaluations.3. MULTIFUNCTIONAL: Audiometer can be used for hearing assessment, screening, and training. Users can choose different modes and perform corresponding operations based on their specific needs.4. CONVENIENT AND USER FRIENDLY: With high accuracy and multifunctionality, it is easy to use and helps users gain a comprehensive understanding of their hearing condition, enabling them to take appropriate protective and improvement measures.5. VERSATILE USAGE: The pure tone audiometer can be used as a fixed installation device. It is suitable for institutions such as hospitals, disease control centers, community centers, industrial enterprises, driving schools, and rehabilitation centers for conducting hearing assessments.Specification:Item Type: Pure Tone AudiometerMaterial: MetalApplicable Range: For individuals with response ability for hearing threshold detectionPartial Performance Specifications are as follows:Test Frequency: Air Conduction (2508000) Hz, Bone Conduction (2506000) Hz, error less than 2%;Test Strength Range: Air Conduction (-10120) dB, Bone Conduction (-1070) dB;Masking Strength Range: (-10110) dB;Distortion: Air Conduction less than 2.5%, Bone Conduction less than 5.5%;Accuracy: Continuous Attenuation/Step 5dB, error less than 1dB.Power Requirement: AC100-240V 50/60Hz 30VAThe working environment temperature of the instrument must be between 15 and 35, relative humidity must be between 30% and 90%, atmospheric pressure must be between 98kPa and 104kPa. Extreme temperatures, humidity, and altitude can all affect the performance of this device.How to Use: 1) Before installing and using the device, please ensure that the surrounding environment is quiet and clean, and keep away from radioactive electromagnetic fields and electronic devices.2) After connecting, power on the device by pressing the green switch button located at the lower right front of the panel. The display screen will turn on and automatically enter pure tone testing.3) Familiarize the subject with the testing procedure.Demonstrate the testing procedure by presenting a test tone of 1000Hz at 40dB HL strength to the subject ear. If the subject can hear the tone, reduce the strength by 40dB. If the subject cannot hear the tone, increase the strength by 40dB until the subject can hear the sound. Then, reduce the strength to the lowest level and gradually increase the sound strength until the subject responds. After a 2-3 second interval, provide the sound again for 2-3 seconds. If the response is consistent, formal testing can proceed.(1) Air Conduction Audiometry (AC)The purpose of air conduction audiometry is to determine the auditory sensitivity at different frequencies. This test can assess air conduction loss but cannot differentiate between conductive hearing loss and sensorineural hearing loss. Air conduction thresholds involve the entire auditory system, including the conductive components of the outer and middle ear, as well as the cochlea and the integrity of the auditory nerve function. It is the fundamental part of audiology evaluation.A) The pure tone audiometer will automatically enter air conduction testing after powering on.B) Position the headphones and ask the subject to remove glasses and jewelry. Place the headphones from the top down and adjust the earmuffs so that the headphones' speaker is directly aligned with the ear canal. Adjust the headband length to ensure that the headphones are secure. If the earmuffs do not contact the ears tightly, there may be significant errors in the low frequency testing results.C) Instruct the subjectBefore the testing begins, explain to the subject about the testing pure tones and the patient response handle button. You will hear different sounds of different strengths through the headphones. When you hear the sound, press the patient response handle button. When you do not hear the sound, release the patient response handle button.D) Order of tested frequencies1000Hz, 1500Hz, 2000Hz, 3000Hz, 4000Hz, 6000Hz, 8000Hz, 250Hz, 500Hz, 750Hz, 1000Hz. Generally, start with the better ear or the healthy ear. If there is a difference of more than 10dB in the thresholds between two 1000Hz tests, retesting should be done. If the thresholds of two octave frequencies differ by 20dB, half octave frequency threshold measurement should be performed. The duration of sound presentation should be 2-3 seconds, and the interval between the presentations should not be shorter than the presentation time. This is because the complete recovery time after adaptation is usually 2-3 seconds, and the presentation time and interval should be irregular. Continuous pure tone testing should
  • Fruugo ID: 326026264-721624848
  • EAN: 7598390762743

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Warning: Please read the product instructions carefully before use to ensure correct use.
일련번호: 7598390762743

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 화 21 10월 2025–월 27 10월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Shenzhenshimutalaikejiyouxiangongsi
  • Shenzhenshimutalaikejiyouxiangongsi
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/