설명
Internal Resistance Tester 6 1/2 Digit 0.1μΩ 1μV Resolution 0‑3.6kΩ 0‑ Range Battery Voltage Resistance Meter
Item Type: Internal Resistance Tester
Material: ABS
Model
HBT3561A
Resistance
Range
3mΩ/30mΩ/300mΩ/3Ω/30Ω/300Ω/3600Ω
Measuring range
0~3.6kΩ
Minimum resolution
0.1μΩ
Voltage
Measuring range
0-110V
Minimum resolution
1μV
Current frequency
1KHz
Input impedance
3mΩ~3600Ω 10MΩ
Open circuit terminal voltage
3mΩ~3600Ω 15V peak
Test anomaly detection display (contact detection)
Detection content: Abnormal connection between Source HIGH LOWHIGH LOW
Abnormal connection between SENSE HIGH LOW display : [------]
Sampling
Sampling rate
Fast/medium/slow (3 levels)
Sampling time
Function
Frequency
Fast speed
Medium speed
Slow speed
ΩV
50Hz/60Hz
60ms
300ms
600ms
Ω
50Hz/60Hz
40ms
200ms
400ms
V
50Hz/60Hz
40ms
200ms
400ms
Time
Response time
Measurement response time: about 5ms
Total measurement time
Time required for the entire measurement: sampling time+response time
Comparator function module
Comparator function
On/Off (shared resistance and voltage)
Comparator settings
Comparator mode: HIGH · LOW/REF ·%
Upper and lower limit values: 0-3600 (resistance)/0-2000 (voltage)
Reference value: 0-3600 (resistance)/0-2000 (voltage)
%Value: 0.000%~99.99% (% range set to+/- universal)
Buzzer mode: Off/HL/IN/BT1/BT2
Comparison mode: automatic/manual
Determine
Judgment result: Hi/In/Lo (independent judgment of resistance and voltage)
PASS/UNPASS determination: Compare the resistance determination result with the voltage determination result
AND operation, followed by PASS/UNPASS output (EXT I/O output)
Test outlier determination: OF Hi determination
-OF Lo determination
Test abnormal - No judgment (no judgment)
Absolute value determination function
Under this function, even if the battery polarity is reversed, it can be compared based on absolute values
Average function
Output the average measurement value, which can reduce the deviation of the displayed value. The average frequency is 1, 2, 4, and 8 times
Delay time
0-9999 milliseconds
Calibration
Voltage calibration/resistance calibration, used to compensate for bias voltage or gain drift within this instrument
Adjustable Zero Range
Resistance measurement: -1000 to 1000 count values
Voltage measurement: -1000~1000 count values (i.e. zero range is less than or equal to ± 1000 dgt.)
Triggering
Internal/External/Manual
Current output
Pulse/Continuous
Storage
On/off/clear, measurement values can be saved to a USB drive through buttons or commands
Statistics
Statistical operations
On/Off/Clear
Calculation content
Average, maximum, minimum, parent standard deviation, sampling standard deviation, process capability index (offset), process capability index (deviation), etc.
Operation triggering
Perform statistical operations on measured values through buttons or commands
Measurement settings saving and reading
Function
Can save and read measurement settings
Save Settings
Measurement type, resistance range, voltage range, automatic range setting
Sampling rate, triggering source, absolute value, delay setting, average setting
Comparator settings, statistical operation settings, communication settings
Button sound
On/Off
Communication interface
HBT3000 series: RS232/485 USB LAN IO ANALOGOUTFUT
-
Fruugo ID:
409330208-866925508
-
EAN:
3331330809559