설명
HP‑42B Portable Digital Multimeter TRMS DC/AC Voltage/Current Resistance 6000 Counts Tester
Condition:
Item Type: Multimeter
Material: ABS
Color: As shown in the picture
Out of Range Display: "OL"
Maximum Display: 6000
Auto/Manual Range Function
Auto-off Function: About 15 minutes after power-on, the meter will automatically power off, press any button to power on again.
Power Supply: 2x1.5V AAA batteries (not included)
Sampling Rate: 2 to 3 times per second
Polarity Display: Negative polarity input display "-"
Low Battery Display: Display symbols
Data Retention: Display symbols "DH"
Relative Value Measurement: Display symbols "REL"
Working Environment: Temperature 0~40℃, relative humidity ≤85%
Storage Environment: Temperature -10~50℃, relative humidity≤85%
DC V
Range
Resolution
Accuracy
600mV
0.1mV
±(0.5% of reading + 5 words)
6V
1mV
±(0.5% of reading + 2 words)
60V
10mV
±(0.5% of reading + 2 words)
600V
100mV
±(0.8% of reading + 2 words)
Overload protection
DC 600V or AC 600V true RMS
Input impedance
10 mΩ, 600 mV gear > 100 mΩ
AC V (True RMS)
Range
Resolution
Accuracy
6V
1mV
±(1.0% of reading + 3 words)
60V
10mV
±(1.0% of reading + 3 words)
600V
100mV
±(1.5% of reading + 3 words)
Input impedance
10 m Ω
Overload protection
DC 600V or AC 600V true RMS
Frequency range
40 hz ~ 2 khz
DC A
Range
Resolution
Accuracy
60mA
10μA
±(1.2% of reading + 2 words)
600mA
100μA
±(1.2% of reading + 2 words)
6A
1mA
±(2.0% of reading + 3 words)
10A
10mA
±(2.0% of reading + 3 words)
Overload protection
F600mA/250V fast-acting fuse; F10A/250V fast-acting fuse
Maximum input current
10A (no more than 10 seconds)
AC A(True RMS)
Range
Resolution
Accuracy
60mA
10μA
±(1.5% of reading + 3 words)
600mA
100μA
±(1.5% of reading + 3 words)
6A
1mA
±(2.5% of reading + 5 words)
10A
10mA
±(2.5% of reading + 5 words)
Overload protection
F600mA/250V fast-acting fuse; F10A/250V fast-acting fuse
Maximum input current
10A (no more than 10 seconds)
Frequency range
40 hz ~ 2 khz
Resistance (Ω)
Range
Resolution
Accuracy
600Ω
0.1Ω
±(1.0% of reading + 3 words)
6kΩ
1Ω
±(1.0% of reading + 2 words)
60kΩ
10Ω
±(1.0% of reading + 2 words)
600kΩ
100Ω
±(1.0% of reading + 2 words)
6MΩ
1KΩ
±(1.0% of reading + 2 words)
60MΩ
10KΩ
±(1.5% of reading + 3 words)
Overload protection
250V DC or AC RMS
Capacitance
Range
Resolution
Accuracy
6nF
1pF
±(5.0% of reading + 10 words)
60nF
10pF
±(5.0% of reading + 10 words)
600nF
100pF
±(3.0% of reading + 10 words)
6μF
1nF
±(3.0% of reading + 10 words)
60μF
10nF
±(5.0% of reading + 10 words)
600μF
100nF
±(10.0% of reading + 20 words)
6mF
1μF
±(10.0% of reading + 20 words)
60mF
10μF
±(10.0% of reading + 20 words)
Overload protection
250V DC or AC RMS
Frequency(HZ)
Range
Resolution
Accuracy
9.999Hz
0.001Hz
±(0.5% of reading + 5 words)
99.99Hz
0.01 Hz
±(0.5% of reading + 5 words)
999.9Hz
0.1 Hz
±(0.5% of reading + 5 words)
9.999kHz
1 Hz
±(0.5% of reading + 5 words)
99.99kHz
10 Hz
±(3.0% of reading + 5 words)
200kHz
100 Hz
±(3.0% of reading + 5 words)
Test sensitivity
1.5V AC RMS
Overload protection
250V DC or AC RMS
Duty Cycle
Measurement range
0.1% ~ 99.9%
Accuracy
±(2.0% reading +2 words)
Frequency below 10kHz and above 10kHz does not guarantee accuracy
Sensitivity
0.6V AC RMS
Overload protection
250V DC or AC RMS
Temperature (℃/℉)
Range
Resolution
Accuracy
-20~150℃
1℃
± (3℃+1 word)
150~1000℃
1℃
± (3% reading +2 words)
-4~302℉
1℉
± (5℉+2 words)
302~1832℉
1℉
± (3% reading +3 words)
NiCr-NiSi
K-type thermocouple
Overload protection
250V DC or AC RMS
Diode test
Resolution
1mV
Function
Read the forward voltage across the diode at an instant
Overload protection
250V DC or AC RMS
Instant DC current
about 1.5mA, reverse DC voltage: about 4V
Continuity
Continuity test
When the component or circuit being measured resistance less than 50 Ω, buzzer sound
Overload protection
250V DC or AC RMS
Open-circuit voltage
About 2V
Non - contact AC voltage (NCV) test
Detection voltage range
90V~1000V AC RMS
When an AC voltage signal is sensed, the red buzzer will light up and the buzzer will sound.
-
Fruugo ID:
416200095-878331957
-
EAN: