Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

₩70,190
무료 배송

Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

  • 브랜드: Unbranded

Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

  • 브랜드: Unbranded
가격: ₩70,190
판매자::
₩70,190
무료 배송

현재 이용 불가

이 아이템이 언제 다시 입고될지 알 수 없습니다.

다음의 결제 방식을 사용하실 수 있습니다

설명

Feature 11602 LCD screen, display information comprehensively 2Configuration of 9cm CPU fan, very quiet 3With temperature display, supporting the discharge and voltage setting 4Test all kinds of power load or burin-in, can also test capacity of battery discharge 5Load maximum power 150W, maximum voltage 60V, maximum current 10ASpecification Description: This is an electronic load board of very high cost performance, adopting two completely independent 18 bit ADC chip, 15 PPM voltage benchmark, which allows a high accuracy. It is better than other electronic load with single chip built-in AD sampling digital tube display or battery capacity tester. Supporting user second correction of parameters, it is a best choice for DIY users. Features: 1602 LCD screen, display information comprehensively. Configuration of 9cm CPU fan, very quiet. With temperature display, supporting the discharge and voltage setting. Test all kinds of power load or burn-in, can also test capacity of battery discharge. Load maximum power 150W, maximum voltage 60V, maximum current 10A. Specifications: Voltage: DC 12V5% Load Type: Constant current Load Voltage: 0.5-60V Load Current: 0-10A Maximum Power: 150W Voltage Reading Precision: (0.1%+0.05%FS) Current Reading Precision: (0.2%+0.1%FS) Constant Current Accuracy: Current reading Precision + 1d Noise: 25dD(A) Weight: 341g(approx.) Instruction: Wiring Diagram of 2 Wires (Safe and convenient): Note: 2 wires must be respectively connected to A+ and A-. V+ is connected to A+, and V- is connected to A-. Wiring Diagram of 4 Wires: Note: 4 wires must be connected completely before use. 4 wires can offset voltage drop caused by electric wires under large current and ensures a more accurate voltage measurement. It is recommended if you are a professional. 4 wires must be all connected correctly before you power on the load. Wrong wiring is likely to cause damage, please make sure the wiring is correct! As you can see in the picture, there are thick wires and thin wires. The thick wires are for current, the thin wires are for measuring voltage, and of course you can use thick wires for all. Below is the operation interface. The operation is very simple and easy(when it displays "ON", it must be connected to load, otherwise it will beep and won't work) Bottom left screen corner will display information that automatic switching between power, AH, temperature, time, and can be set to always display certain one. "I": Setting load current "V": Setting discharge cut-off voltage. 1, the power adapter: DC 12V, load power and power supply should be 2 independent power. 2, Power on and screen shows "Welcome to use" which means equipment is normal 3, Press "set" to move the cursor, add and subtract operations according to the cursor position. When the cursor position is at "I" or "V", press "add" or "subtract" button to switch current and voltage setting. 4, Connect to power source that need to be tested, and make sure the wiring is correct. 5, Press "start" button to start/stop electronic load, and screen shows "ON" or "OF" 6, Press and hold "start" button for more than 1 second to reset AH and time, and power off the electronic load (if it was powered on) 7, The bottom left screen corner will display information that automatic switching by default every 2 seconds between power, AH, temperature, time. Press and hold "set" button, then press "add" button to switch, and the display information will not switch automatically. If you need the information to switch automatically again, press and hold "set" button, then press "subtract" button till bottom right screen corner shows "Auto". 8, Settings will be automatically saved after power failure. Electric loaf need to be manually started when power is back. 9, Continuous operation power of load is associated with operating temperature. When temperature is too high, operation power should be reduced. If the heat sink temperature reaches 87 , the load will automatically reduce power. When the core temperature reaches 91 , it will stop work, and need to be manually started after cooling. 10, Load current will be automatically adjusted according to the input voltage. For example, if set 10A, and the input voltage is 20V, then it automati
  • 브랜드: Unbranded
  • 카테고리: 센서
  • Fruugo ID: 196667684-419360283
  • EAN: 4142380075646

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Please use and store the product correctly according to the instructions

배송 및 반품

-1일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 목 16 10월 2025–월 27 10월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Shenzhen Yangxi Trading Co., Ltd.
  • Shenzhen Yangxi Trading Co., Ltd.
  • No. 203, No. 3, Lane 3, Houshan West, Xiaxue Village, Xinxue Community, Bantian Street, Longgang
  • Shenzhen
  • CN
  • 518129
  • wqvkk3@163.com

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
  • Frankfurt am Main
  • ES
  • 28947
  • successservice2@hotmail.com
  • 34910602659