설명
Dso5102p Digital Oscilloscope 100mhz 2 Channels 1gsa/s 7inch Tft Lcd
Features:100MHz bandwidths.1GSa/s Real Time sample rate.Large (7.0-inch) color display, WVGA(800x480).Record length up to 40K.Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.USB host and device connectivity, standard.Multiple automatic measurements.Four math functions, including FFTs standard.Provides software for PC real-time analysis.Specifications:Size: 14 x 11x 32cm/5.51 x 4.33 x 12.60inchWeight: 2900gModelDSO5102PAcquisitionSample RateReal-Time Sample: 1GS/sEquivalent Sample: 25GS/SAcquisition ModesNormalNormal data onlyPeak DetectHigh-frequency and random glith captureAverageWaveform Average, selectable 4.8.16.32,64,128InputsInputs CouplingAC, DC. GNDInputs Impedance1M2%ll20pF3pFProbe Attenuation1X,10XSupported Probe Attenuation Factor1X,10X,100X,1000XMaximum Input VoltageCAT I and CAT II: 300VRMS (10x), Installation Category;CAT III: 150VRMS(1x);Installation Category II: derate at20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.HorizontalSample Rate Range500MS/S - 1GS/SWaveform Interpolation(sin x)/xRecord Length40KSEC/DIV RangeSample Rate and Delay Time Accuracy50ppm (at over any 1ms time interval)Position Range20ns/div to 80us/div; (-8divx s/div) to 40ms;200us/div to 40s/div; (-8divx s/div) to 400sDelta Time MeasurementAccuracy(Full Bandwidth)Single-shot. Normal mode: (1 sample interval +100ppm x reading + 0.6ns); >16 averages:
(1 sample interval + 100ppm x reading + 0.4ns);Sample interval = s/div / 200VerticalVertical Resolution8-bit resolution, all channel sampled simultaneouslyPosition Range2mV/div to 200mV/div, 2V 200mV/div to 5V/div, 50VBandwidth100MHzRise Time at BNC( typical)3.5nsAnalog Bandwidth in Normal and Average modes at BNC or with probe. DC Coupled2mV/div to 20mV/div, 400mV; 50mV/div to 200mV/div,2V 500mV/div to 2V/div, 40V; 5V/div, 50VMath+, - ,x, /, FFTFFTWindows: Hanning. Flatop. Rectamgular, Bartlett. Blackman; 1024 sample pointBandwidth Limit20MHzLow Frequency Response (-3db)10Hz at BNCDC Gain Accuracy3%for Normal or Average acquisition mode. 5V/div to 10mV/div;4% for Normal or Average acquisition mode. 5mV/div to 2mV/divDC Measurement Accuracy, Average Acquisition ModeWhen vertical displacement is zero, and N s16: (3% x reading + 0.1div+ 1mV)only 10mV/div or greater is selected;When vertical displacement is not zero, and Ns16: (3% x (reading + vertical position) +1% of vertical position + 0.2div); Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability, Average Acquisition ModeDelta volts between any two averages of si 6 waveforms acquired under same setup and ambient conditionsTrigger SystemTrigger TypesEdge. Video. Pulse. Slope. Overtime. AlternativeTrigger SourceCH1f CH2, EXT, EXT/5, AC LineTrigger ModesAuto, Normal, SingleCoupling TypeDC, AC, Noise Reject, HF Reject. LF RejectTrigger Sensitivity (Edge Trigger Type)DC(CH1.CH2):1 div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT):200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;DC(EXT/5):1Vfrom DC to 100MHz; 1.
-
Fruugo ID:
363451606-788707943
-
EAN:
8988018592095