Digital Multimeter High Accuracy Inductance Capacitance Resistance Tester LCR Meter with NCV Function

₩52,790
무료 배송

Digital Multimeter High Accuracy Inductance Capacitance Resistance Tester LCR Meter with NCV Function

  • 브랜드: Unbranded
판매자::

Digital Multimeter High Accuracy Inductance Capacitance Resistance Tester LCR Meter with NCV Function

  • 브랜드: Unbranded

₩52,790

할인 ₩15,800 (23%)

권장소매가

₩68,590
재고 있음
무료 배송

14일 반품 정책

판매자::

₩52,790

할인 ₩15,800 (23%)

권장소매가

₩68,590
재고 있음
무료 배송

14일 반품 정책

결제 방법:

설명

Digital Multimeter High Accuracy Inductance Capacitance Resistance Tester LCR Meter with NCV Function

Feature:1. [High Accuracy Digital Multimeter] This multimeter offers minimal errors and ensures accurate measurement data, making it a reliable tool for various measurement tasks.2. [NCV Function] Equipped with a non contact voltage (NCV) feature, this multimeter allows for safe and convenient voltage measurements without direct contact.3. [Compact and Portable] With a compact body, this inductance capacitance resistance tester is easy to carry, making it convenient for travel maintenance tasks.4. [Backlit Screen Display] The LCR meter features a backlit screen that provides clear visibility, allowing for easy reading of measurements in any complex or dark environment.5. [User Friendly] The digital multimeter is designed with clear markings, enabling even beginners to quickly and easily start using the device.Specification:Item Type: Digital MultimeterMaterial: ABSBattery Model: 1.5V AAA Battery x 2 (Not Included)Battery Type: Dry BatteryDC Voltage (V)(mV): 6V 60V 600V 1000V 60mV 600mV Accuracy: (0.5%+3)AC Voltage (V)(mV): 6V 60V 600V 750V 60mV 600mV Accuracy: (1%+3)DC Current (A)(mA): 6A 10A 60mA 600mA Accuracy: (1.2%+3)AC Current (A)(mA): 6A 10A 60mA 600mA Accuracy: (1.5%+3)Inductance: 6mH Accuracy: (5%+50) 60mH 600mH 6H Accuracy: (3%+10) 60H Accuracy: (5%+50)Resistance: 600 6k 60k 600k 6M Accuracy: (0.5%+3) 60M Accuracy: (1.5%+3)Capacitance: 6nF 60nF 600nF Accuracy: (5%+20) 6F 60F 600F Accuracy: (2%+5) 6mF 60mF Accuracy: (5%+5)Frequency: 99.99Hz 999.9Hz 9.999KHz 99.99KHz 999.9KHz 10MHz Accuracy: (0.1%+2)Duty Ratio: 1%~99% Accuracy: (0.1%+2)Continuity: <50Diode: Forward DC Current About 5mA, Voltage About 3.9VTemperature: -20~1000 -4~1832 Accuracy: (2.5%+5)Preparation1. When using the instrument, users must adhere to standard safety rules:General guard against electric shockPrevent misuse of the instrument2. Upon receiving the instrument, check for any damage during transport3. After storing and shipping in rough conditions, check and confirm if the instrument is damaged4. The test cables must be in great condition. Before use, check if the insulation of the test cables is damaged and if the metal wire of the leads is exposed5. Using the test cables provided with the instrument can ensure safety, and if needed, they must be replaced with the same or equivalent grade of test cablesUse1. When using, make sure to use the correct function and range2. Do not exceed the indicated values for the guard range of each range during measurement3. When connecting the instrument to the measuring circuit, do not touch the tip (metal part) of the test cables4. During measurement, if the measured voltage is higher than 60V DC or 30V AC (rms), pay attention to keep your fingertips behind the test cable guard5. Do not measure voltage if the voltage between the measurement terminal and ground exceeds AC1000V6. Before rotating the selector switch to change the measurement function, remove the test leads from the measured circuit7. Do not measure resistance, capacitance, diodes, and circuit continuity with electricity8. During the current, resistance, capacitance, diode, and line on off test range, care should be taken to avoid connecting the instrument to a voltage source9. Before the capacitor is completely discharged, do not measure the capacitance10. Do not use this instrument near explosive gases, vapors, or dust11. If any abnormalities or malfunctions are noticed in the instrument, it should be stopped from use12. Unless the instrument bottom shell and battery cover are completely fastened in place, the instrument should not be used.Package List:1 x Digital Multimeter1 x Cloth Bag2 x Test Cable1 x Temperature Probe1 x User Manual
  • Fruugo ID: 416503909-878855369
  • EAN: 7540131482526

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Warning: Please read the product instructions carefully before use to ensure correct use.
일련번호: 7540131482526

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 목 05 2월 2026–목 12 2월 2026 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Wuhan Pinsheng Technology Co., Ltd.
  • Wuhan Pinsheng Technology Co., Ltd.
  • No.A357,Shoulder-to-shoulder?Incubator,Building?4
  • Wuchang District
  • Wuhan
  • CN
  • 430000
  • pinsenkj@163.com
  • 18062524796
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795