Df-96ed Automatic Water Level Controller 10A 220V Tank Liquid Level Detection Sensor Cistern Pump Switch

₩48,290
+ ₩10,499 배송

Df-96ed Automatic Water Level Controller 10A 220V Tank Liquid Level Detection Sensor Cistern Pump Switch

  • 브랜드: Unbranded

Df-96ed Automatic Water Level Controller 10A 220V Tank Liquid Level Detection Sensor Cistern Pump Switch

  • 브랜드: Unbranded
희망소매가격: ₩96,590
가격: ₩48,290
절약 금액: ₩48,300 (50%)
판매자::
₩48,290
+ ₩10,499 배송

재고 있음

14일 반품 정책

결제 방법:

설명

Df-96ed Automatic Water Level Controller 10A 220V Tank Liquid Level Detection Sensor Cistern Pump Switch

100% Brand New and High Quality. Features: Made of high-quality material, strong, durable, and with a wide effective range, providing you with a long service life. It automatically controls the drainage of water from the tank and the effective water level of the pool to prevent overflow or significant damage when the pump runs dry. With full or lack of water protection, this regulator protects the pump from burning out. It also controls the upper and lower pools simultaneously. Mounting on a guide rail can be installed in a distribution box for quality assurance. It comes with 3 probes that can be easily adjusted as needed to monitor the water level. Ideal for pressure and dyeing projects of well water, chemicals, beverages, wine, sugar, and other industries. 1 x Automatic Water Level Regulator only, other accessory demos in the picture are not included. Specification: Model: DF-96ED Material: Flame Retardant Size: approx. 88 x 49 x 67 mm / 3.46 x 1.93 x 2.64 inches Working Voltage: 220 V Current: 30 A Power: 2W Color: As the picture shows Quantity: 1 set Instructions: 1. Installation of the single control upper pool (water storage): A (red wire) is the highest water level of the upper pool. When the water level reaches point A, the probe connects to the water, and the regulator automatically turns off the pump. B (blue wire) is the lowest water level of the upper pool. When the water level is lower than point B, the probe disconnects from the water, and the regulator automatically turns on the pump to supply water. C (black wire) is the ground wire, placed in the lowest part of the pool but not at the bottom. It is recommended to place the ground wire lower than point B in a metal water tank. (The probe should stay away from the tank wall.) D (green wire) and E (yellow wire) are connected to C (black wire). 2. Installation of a single control lower pool (draining water): E (yellow wire) is the highest water level of the lower pool. When the water level reaches point E, the probe connects to the water, and the regulator automatically turns off the pump to drain water. D (green wire) is the lowest water level of the lower pool. When the water level is lower than point D, the probe disconnects from the water, and the regulator automatically turns on the pump to stop draining water. C (black wire) is the ground wire, placed in the lowest part of the pool but not at the bottom. It is recommended to place the ground wire lower than point D in a metal water tank. (The probe should stay away from the tank wall.) A (red wire) and B (blue wire) are disconnected. 3. Installation of no water protection: C and D are the lowest water level of the lower pool. When the water level reaches the lowest level, C or D will disconnect from the water, then the regulator will automatically turn off the pump. E (yellow wire) and C (black wire) are short-circuited. A (red wire) and B (blue wire) are disconnected. 4. Installation of common control of HIGH and LOW pool: A (red wire) is the highest water level of the upper pool. When the water level reaches point A, the probe connects to the water, and the regulator automatically turns off the pump. B (blue wire) is the lowest water level of the upper pool. When the water level is lower than point B, the probe disconnects from the water, and the regulator automatically turns on the pump to supply water. C (black wire) is the ground wire in the upper and lower pools, placed in the lowest part of the pool but not at the bottom. It is recommended to place the ground wire lower than point BD in a metal water tank. (The probe should stay away from the tank wall.) D (green wire) is the lowest water level of the lower pool. When the water level reaches point D, the probe disconnects from the water, and the regulator
  • 브랜드: Unbranded
  • 카테고리: 홍수
  • Fruugo ID: 397854700-848333866
  • EAN: 6902419414161

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Not suitable for children under 36 months
재료: Plastic 5%

배송 및 반품

24시간 이내에 발송됨

  • STANDARD: ₩10,499 - 배달 사이 화 30 12월 2025–수 07 1월 2026

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • DIMEANI06
  • Wenzhou Xianrui E-commerce Co., Ltd.
  • 1020, 10th Floor, Wenzhou Premium Agricultural Products Exhibition and Sales Center Building,
  • Zhejiang Southern Agricultural and Sideline Products Center Market (Area 4)
  • Wenzhou
  • CN
  • 325029
  • smarthomebrand@outlook.com
  • 8619146916074

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • E-CrossStu GmbH
  • E-CrossStu GmbH
  • Mainzer Landstr.69
  • 60329 Frankfurt am Main
  • Hessen
  • DE
  • 60329
  • E-CrossStu@web.de
  • 69332967674