설명
Key benefits
- Prevents damage from end-of-travel conditions by using a reliable limit (stop) signal that halts movement during forward rotation.
- Safe behavior persists even if the limit signal disappears; the motion remains stopped until the forward rotation signal is reactivated.
- Self-locking PO versions provide latching forward motion with automatic stopping at designated end signals, enhancing control and predictability.
- Flexible wiring and sensor compatibility simplify integration with existing control systems.
What it is and how it works
- Limit signal
- The limit signal is also known as a stop signal.
- It is a trigger type and level-activated signal.
- If a short limit signal occurs during forward rotation, the movement stops.
- Even if the limit signal disappears, it remains stopped. To move forward again, the forward rotation signal must be restarted.
- PO versions (self-locking)
- PO versions are self-locking.
- When the external forward switch K1 is pressed, the motor rotates forward.
- After the switch is released, the motor continues to rotate forward.
- It stops only when it encounters the reverse turn signal K2 or the forward turn stop signal SW1.
- Signal requirements and sensor compatibility
- The signal is active low.
- It can be a three-wire sensor (NPN-NO type).
- The signals K1, K2, SW1, and SW2 comply with this specification.
Compatibility and wiring details
- Signal type: active low
- Sensor options: three-wire NPN-NO type supported
- Control inputs: K1, K2, SW1, SW2 are designed to comply with the active-low, three-wire sensor compatibility
Use scenarios
- Conveyor or feed line end travel
- A limit signal detects the end of travel for a conveyor segment. If triggered, the line stops automatically. The signal’s persistence after triggering ensures a safe halt, and reactivation of the forward input resumes motion only when intended.
- Automated gate or door control
- The system uses K1 for forward motion and K2 or SW1 to stop. The self-locking PO option provides reliable forward motion until an end signal is reached, improving safety and timing in access control.
- Small automation station with manual forward control
- Operators press K1 to advance to a stop at the end signal. If the limit is reached or the end signal is activated, motion stops and requires re-engagement of forward input to proceed, reducing accidental overshoot.
Technical notes
- Limit signal applies as a stop condition during forward rotation
- Restart of forward motion after a stop is initiated by reactivating the forward input
- Compatible with standard control configurations using K1, K2, SW1, SW2
- Sensor wiring follows the active-low, three-wire NPN-NO convention
This description maintains the original product specifications, models, and functional behavior while presenting clear, practical guidance for use, compatibility, and real-world applications.
-
브랜드:
Unbranded
-
카테고리:
가전 제품
-
Fruugo ID:
393219408-840808875
-
EAN:
899196897606