DC 6-30V Trigger Delay Timer Relay Switch Module with Digit LED Display & Micro USB 5V

₩48,790
+ ₩14,199 배송

DC 6-30V Trigger Delay Timer Relay Switch Module with Digit LED Display & Micro USB 5V

  • 브랜드: Unbranded

DC 6-30V Trigger Delay Timer Relay Switch Module with Digit LED Display & Micro USB 5V

  • 브랜드: Unbranded
희망소매가격: ₩115,790
가격: ₩48,790
절약 금액: ₩67,000 (57%)
판매자::
₩48,790
+ ₩14,199 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Features:Wide DC power supply voltage from 6V to 30V, support micro USB 5.0V power supply, very convenient to use.Interface is clear, simple and powerful, easy to understand, almost meet all your needs.The module supports reverse input protection, and there is a STOP button for emergency stop function. Added sleep mode, it will automatically turn off display if no operation in 5 minutes after enabled, and you can press any button to wake it up.You can set different OP, CL, LOP parameters, these parameters were independent of each other and saved respectively.All set parameters will be automatically saved if there is a power failure.With optical coupling isolation, improved anti-interference ability, industrial level circuit board.Specifications:Voltage: 6V-30V(support micro USB 5.0V)Quiescent Current: 20mAOperating Current: 50mAOperating Temperature: -40-85Size: Approx. 6.2x3.8x1.7cm or 2.44x1.49x0.67"Timing Range: 0.1seconds to 999 minutes(continuously adjustable)Instruction:Operation Mode:P1: After triggering signal, switch isconnected for "OP"time, then disconnected within the "OP"time:P1.1:if trigger signal again,it isinvalid.P1.2: if trigger signal again, restart timing.P1.3: if trigger signal again, switch is disconnected, stop timing.P-2: After triggeringsignal, switch is disconnected for "CL"time, then switch is connected for "OP"time, and disconnect after timing.P3.1: After triggering signal, switch is connectedfor "OP"time, then switch is disconnected for "CL"time, and enter loop. Iftrigger signal during loop, switch is disconnected and stop timing. The loop times(LOP) can be set.P3.2: After power on, no need triggersignal, switch will be connected for "OP"time, then disconnected for "CL"time, and enter loop. The loop times (LOP) can be setP-4: Signal holding function. If there is triggersignal, timing will be reset, switch remains connected when the signaldisappears, it will disconnect after "OP"time. During timing, if there is asignal, timing will be reset.OP: Connect time. CL: Disconnect time. LOP:Loop times(1-999, "- -"indicates infinite times)All above parameters are independent fromeach other, but all modes use the same parameters. For example, if set OP timeas 5 seconds in P1.1, then change to P1.2, then the OP time in P1.2 will also be5 seconds.Press SET button at the main interface (display000), it will show OP(CL, LOP) and corresponding time.If there is only OP mode (e.g. P1.1,P1.2, P1.3), press SET button todisplay OP and corresponding time only.If there are OP, CL, LOP modes (e.g.P3.1,P3.2), press SET button to display OP, CL, LOP and corresponding time.After setting mode, press SET button at themain interface to check the parameter of present mode.How to Choose Timing Range:After setting parameter in the interface selectionmode, press the STOP button to select the time range:XXX. If the last decimalpoint lights up, the time range is 1sec to 999sec.XX.X If the second lastdecimal point lights up, the time range is 0.1sec to 99.9sec.X.X.X.If all decimal pointslight up, the time range is is 1 min to 999 min.For example, if you set OP as 3.2 seconds,the make the second last point light up, and it displays 03.2How to Set Parameter:1. Make sure operation mode.2. According to the operation mode, at maininterface(after power on, it will flash present mode then enter main interface),press and hold SET button for 2 seconds to enter mode selection interface, thenpress UP, DOWN button to choose mode (P1.1-P-4) 3. After selecting mode, press short SET buttonto set the corresponding parameter, then the parameter you want to set willflash. Press UP, DOWN button to set value, then press STOP button to selecttime range. Press SET button to set next parameter.4. After setting mode parameter, press andhold the SET button for 2 seconds then the present mode will flash, and go backto the main interface.Main interface: when relay does not work,it shows "000" (no decimal point) when relay is working, it shows decimalpointMode Selection Interface: Press and hold SETbutton to enter. After setting, press and hold SET button to back to maininterface.Relay Enable Mode:1. NO: Connection is allowed during OP time.2. OFF: Connection is not allowed, always turnedoff.Press STOP button at main interface tochange between ON and OFF, the present state will flash then back to maininterface. (This is emergency stop function, used to disconnect relay.)Sleep Mode:C-P sleep mode: if no operation within 5minutes display will close automatically while procedure runs normally.O-d normal mode: displays always shows.Press and hold STOP button for 2 seconds tochange between C-P and O-d, present state will flash and then back to the maininterface.Package Includes:1 x Timer Switch ModuleNote:Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering. .
  • 브랜드: Unbranded
  • 카테고리: 반도체
  • Fruugo ID: 433705247-910419444
  • EAN: 9421285345784

배송 및 반품

2일 이내에 발송됨

  • STANDARD: ₩14,199 - 배달 사이 월 24 11월 2025–금 28 11월 2025

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • The Marble Market
  • Shenzhen Hongyi Lighting Co., LTD
  • Room 2011, Wantong Building, No. 3002, Sunqiao East Road, Sunqiao Sub-district, Luohu District, Shenzhen City
  • shenzhen
  • CN
  • 518023
  • Charllle@163.com
  • 18776132396

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • Jean Luc
  • In Memoria Futuri SAS
  • 3 RUE DU PAS DE LA MULE 75004 PARIS
  • Paris
  • France
  • 75004
  • infoapexchen@gmail.com
  • 33745713901