Battery Power Monitor Multifunctional Voltage Current Coulometer APP Control 0‑120V 0‑400A

₩79,090
+ ₩7,749 배송

Battery Power Monitor Multifunctional Voltage Current Coulometer APP Control 0‑120V 0‑400A

  • 브랜드: Unbranded

Battery Power Monitor Multifunctional Voltage Current Coulometer APP Control 0‑120V 0‑400A

  • 브랜드: Unbranded
희망소매가격: ₩98,890
가격: ₩79,090
절약 금액: ₩19,800 (20%)
판매자::
₩79,090
+ ₩7,749 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Battery Power Monitor Multifunctional Voltage Current Coulometer APP Control 0‑120V 0‑400A

Battery Power Monitor Multifunctional Voltage Current Coulometer APP Control 0‑120V 0‑400A Item Type: Battery Monitor Model: KL140F Material: ABS Application: Electric power value detection Control Method: Mobile APP Sampling Method: Sampler Voltage Measurement Range (External Power Supply): 0~120V Voltage Measurement Range (Self Power Supply): 10V~120V Voltage Resolution: 0.01V Current Measurement Range: 0~400A Current Resolution: 0.1A Relay: No relay is provided, you need to configure it yourself Temperature Measurement Range: -20℃~120℃ Capacity Display Range: 0%~100% Power Measurement Range: 0~72KW Power Resolution: 0.01W AH Measurement Range: 0~9999.99AH Capacity Resolution: 0.001AH WH Measurement Range: 0~9999.99kWH WH Resolution: 0.01WH Bluetooth Communication Distance: Maximum Approx. 10 meter / 32.8ft (barrier free) Voltage Accuracy: ±2%+3 words Current Accuracy: ±5%+10 words Sampling Rate: 1 time/second Measurement Board Power Consumption: About 0.4W Over Power Protection: 0~99999.99W Negative Overcurrent Protection: 0~50A/100A/400A/600A Forward Overcurrent Protection: 0~50A/100A/400A/600A Overvoltage Protection: 0~120V/600V Under Voltage Protection: 0~120V/600V External Over Temperature Protection: 0℃~120℃ Mobile Terminal Control:  1. For Android mobile APP Instruction (1) Download the APP (2) Mobile App software installation. This software only supports for Android 5.0 and above systems. During the installation process, you will apply for positioning services. Please agree and open the positioning services. This manual corresponds to software version 1.0, and different versions may be slightly different. It is recommended to upgrade to the latest software for a better user experience. 1. For iPhone mobile APP Instruction (1) Download the APP and search for KL series in the software store to download. (1) Mobile APP software installation, the software only supports for iOS 9.0 and above systems, the software will be accessed when the software is connected to Bluetooth for the first time, please agree to access Bluetooth. This manual corresponds to software version 1.0, and different versions may be slightly different. It is recommended to upgrade to the latest software for a better user experience. (3) Software update, you can get the latest software from the software store. The for iOS software version corresponding to the current manual is 1.0. Wiring :  1. Self Powered Wiring Mode: If the voltage range of the battery under test is between 10-120V, the self powered wiring method can be used. First, turn the power supply selection interface switch to 2W, and then connect the positive pole of the battery to the battery. At the power supply interface Vsns, this line does not need to be particularly thick, 1-2.5 squarelines can be used, be careful not to connect the positive pole of the battery incorrectly. The negative electrode of the battery is connected to the screw marked with the battery GND mark on the sampler. The negative electrode of the charger and the negative electrode of the load are connected to another screw of the sampler. It is better e a copper nose to connect firmly; The current color is green, the remaining capacity value increases, and the current color is sky blue during discharge, and the remaining capacity value decreases. 2. External Power Supply Wiring Method: The voltage range of external power supply measurement is 0-120V. First, turn the power supply selection interface switch to 3W, connect the positive pole of the external power supply to the power supply interface VEXT, and connect the negative pole of the external power supply to GND; Then connect the positive pole of the battery to the measurement interface Vsns in the power supply interface when wiring; note that the positive and negative poles of the external power supply should not be connected incorrectly or reversely. The negative electrode of the battery is connected to the screw marked with the battery GND mark on the sampler. The negative electrode of the charger and the negative electrode of the load are connected to another screw of the sampler. It is better e a copper nose to connect firmly; The current color is green, the remaining capacity value increases, and the current color is sky blue during discharge, and the remaining capacity value decreases. 3. Connection Method of External Power Supply to Relay: The working power of the relay is provided by the external power supply. If the relay is connected, an external power supply with the same working voltage as the relay should be provided. Connect the control ports of the relay to the OUT and VEXT of the Output Control of the measurement module respectively; connect the positive pole of the external power supply to the VEXT of the Output Control, and the negative pole of the external power supply to GND; be careful not to connect the positive and negative poles of
  • Fruugo ID: 403121039-855960103
  • EAN: 9361326327143

배송 및 반품

24시간 이내에 발송됨

  • STANDARD: ₩7,749 - 배달 사이 수 10 12월 2025–금 19 12월 2025

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기