Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

₩23,390
무료 배송

Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

  • 브랜드: Unbranded

Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

  • 브랜드: Unbranded
희망소매가격: ₩41,390
가격: ₩23,390
절약 금액: ₩18,000 (43%)
판매자::
₩23,390
무료 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Features 1、An additional signal output. When the relay conduction condition is met, the module will output high level to control other devices. 2、With serial port communication function, the working status of the relay can be monitored in real time through the serial port. 3、Charge and discharge time can be set, and the battery charging board will automatically power off after setting. 4、There is a key emergency stop function (STOP key). With reverse connection protection, the reverse connection will not burn. 5、This battery charging module is designed for the batteries below 60V, and the error in voltage measuring is less than 0.1V. Specification Item Type: Battery Charge and Discharge Module Product Material: Printed Circuit Board Product Parameters: 1: Power supply voltage: DC6--40V; Voltage Detection Range: DC 0--60V; Suitable for various batteries below 60V; Voltage Test Error: ±0.1V; 2: Charge and discharge time (OP) range: 0-999 Minutes. How to Use: 1. First determine the working mode of the relay; 2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default U-1 mode), and then enter the main interface,) "Long press the SET button for 2 seconds and then release” to enter the mode selection interface, and select the mode (U-1~U-6) by short pressing the UP and DOWN buttons; 3. After selecting the mode (such as U-1), short press the SET button to set the corresponding parameters. At this time, the parameters to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), and press UP, DOWN to adjust the parameter value, supports long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); short press the SET key to set the next parameter of the current mode, the process is the same as above; 4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release it. The currently set mode will flash, and then return to the main interface. The parameter setting is successful, very simple! 5. On the main interface, short press the DOWN button to switch between voltage and time, which is very simple. Mode Selection Interface: Long press the SET button to enter, after the setting is completed, long press the SET button to exit and return to the main interface, very simple! Operating Mode: Voltage Upper Limit: UL1, Voltage Lower Limit: nL1, voltage upper limit must be greater than voltage lower limit (UL1>nL1) U-1: Charging Measurement: When the measured voltage is lower than the lower limit voltage, the relay is closed, and higher than the upper limit voltage, the relay is disconnected; U-2: Charging Measurement Time Control: Set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the voltage is higher than the upper limit voltage, the relay disconnect. U-3: Discharge Detection: When the measured voltage is lower than the lower limit voltage, the relay is disconnected, and when the measured voltage is higher than the upper limit voltage, the relay is closed; U-4: Discharge Detection Time Control: Set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the measured voltage is lower than the lower limit Voltage, the relay is off; U-5: Closed in the Interval: When the measured voltage is between the upper limit and the lower limit, the relay is closed, otherwise it is disconnected; U-6: Pull-in Outside the Interval: When the measured voltage is lower than the lower limit voltage or higher than the upper limit voltage, the relay is pulled in, and the relay is disconnected in other cases; Package List 1 x Battery Charge Discharge Module
  • 브랜드: Unbranded
  • 카테고리: 변조기
  • Fruugo ID: 271670617-602232403
  • EAN: 9308869135996

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 수 15 10월 2025–화 21 10월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기