Specifications:
Timing range: 0-999s,0-999m,0-999h
Power supply voltage: DC12V /AC 110V 220V
Relay: 20A
Working current: 10A(maximum)
Power: 1500W (maximum)
Size: 79 x 26 x 43mm/2.99" x 1.02" x 1.69"
Hole size: 72 x 40mm/2.83" x 1.57"
Instruction Manual:
1.After setting the data, you must wait 6 seconds,6s post modules automatically save memory set data.
2.Press SET key once to enter the time setting mode,the red LED flashes, press the key to increase or decrease the setting time T1.
3.After setting time T1,short press the SET key again, the green LED flashes,and the time is set by pressing the key Time T2, T2 time setting is completed,press SET key again, the system will automatically save the memory setting time or wait for 6s, 6s module will automatically save the data memory.
4.Long press SET,enter parameter setting mode.There are two sets of parameters for the user to select P0, P1.Short press SET in the current mode to switch between P0 and P1.
5.In P0 parameter can be set by pressing the key to adjust their own timing mode.In the P1 parameter can be set by adding and subtracting keys work mode.
P0--0:T1 Timing mode is second.
P0-1: T1 timing mode is minutes.
P0--2:T1 Timing Time mode is hour.
P1--0:Delay T1 time,relay pull(T1 timer)
P1--1:Relay release after T1 time delay (T1 timer)
P1--2:Delay T1 time,relay pull(T1 timer),and then relay release after T2 time delay(T2 timing),then it is finished.
P1--3:Relay release after T1 time delay(T1 timer),then delay T2 time,relay pull(T2 timing),then it is finished.
P1--4:Delay T1 time,relay pull(T1 timer),and then relay release after T2 time delay(T2 timer),cycling.
P1--5: Relay release after T1 time delay(T1 timer),then delay T2 time,relay pull(T2 timer),cycling.
Package Included:
1 x Dual Display Time Delay Relay
Working voltage=voltage indicated on the label
S1 and S2 have no output
Reminder
When the label indicates voltage=load working voltage
The time controller can share the power supply with the load
Common AC power supply
Common DC power supply
Code parameter setting
1. Enter the code parameter setting interface
Press and hold the "S key for 6 seconds to enter the code parameter setting interface
2ClickorAdjust parameter value
3. Click the "S" key to switch the code, and continue to click to exit the setting
3P0 code parameter meaning: timing unit
P0=0
Unit=seconds (default)
P0=1
Unit=minutes
P0=2
Unit=Hour
4P1 code parameter meaning: working mode
P1=0=Start regularly
Power off the load first
The load remains energized at the end of the time
P1=1=
Scheduled shutdown
Power on the load first
End of time, keep the load powered off and shut down
P1=2=Alternating switch
The load is powered on and then powered off alternately once
End of time, keep the load powered off and shut down
P1=3=Alternate closing and opening
The load is powered off and then powered on alternately once
The load remains energized at the end of the time
P1=4=Cycle Off
The load is powered off before being powered on
Infinite loop
P1=5=
Cycle switch
Load is powered on before power off
Infinite loop
Timing parameter setting
1. Enter the code parameter setting interface
Double-click the S key to enter the code timing parameter setting interface
2ClickorAdjust parameter value
3. Click the "S" key to switch the code, and continue to click to exit the setting
Resume by Alarm
1. Delayed startup means that the power is cut off first and then kept on. It is assumed that the startup needs to be delayed for 6 seconds. Then the code parameter is set to P0=0; P1=0, set the timing parameter PV nixie tube to 6, and SV ignores the setting.
Scheduled shutdown setting
1. Delayed shutdown means power-on and then power-off. It is assumed that the shutdown needs to be delayed for 6 seconds. Then the code parameter is set to P0=0; P1=1, set the timing parameter PV nixie tube to 6, and SV ignores the setting.
Alternate switch 1 time setting
Power off first and then power on alternately for 1 time, and then keep power off without cycling
Suppose you need to shut down for 100 seconds, then turn on for 50 seconds, and finally shut down. Then the code parameter is set to P0=0; P1=2, set the timing parameter PV nixie tube to 100 and SV nixie tube to 50.
Power on first and then power off alternately once, and then keep power on without cycling
Suppose you need to turn on the machine for 100 seconds, then turn off the machine for 50 seconds, and finally turn on the machine. Then the code parameter is set to P0=0; P1=3, set the timing parameter PV nixie tube to 100 and SV nixie tube to 50.
Infinite cycle switch setting
Power off before power on infinite cycle
Suppose you need to shut down for 100 seconds, then start up for 50 seconds,
-
Fruugo ID:
263899193-580783714
-
EAN:
9022455130676
제품 안전 정보
아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.
以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。
제품 안전 라벨
안전 경고:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
재료:
Octinoxate 7.9%
제조업체 부품 번호:
XWH659085
모델 번호:
XWH769974
일련번호:
XWH781195
배치 번호:
XWH537184