5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

₩17,790
+ ₩8,049 배송

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • 브랜드: Unbranded

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • 브랜드: Unbranded
희망소매가격: ₩27,790
가격: ₩17,790
절약 금액: ₩10,000 (35%)
판매자::
₩17,790
+ ₩8,049 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

5V - 24V Motor Forward / Reverse Controller Timing Delay Time Cycles Relay Features: Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V    Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA.    There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).    Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode    Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.    Cycle times: no cycle, 2-99 cycles, always cycle.    Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).    Relay load current, recommended less than 5A. This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings. Port:       DC 5.5MM female : Power supply 1, DC 5V power supply.  VIN: Power 2 positive, DC 6.5-25V power supply  GND: Power supply 2 negative  FWD: Forward input control (partial Function-Mode is invalid)  REV: Reverse input control (partial Function-Mode is invalid)  STOP : Stop input control (partial Function-Mode is invalid)  M+: Motor positive   M-: Motor negative  P+: Positive terminal for motor power supply P-: negative terminal for motor power supply   Specification: Power supply: DC 6.5-25V, DC 5V Working current: 83mA Standby current: 41mA Relay load current: <5A Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes Size: 8*5cm/3.2*2in Weight: Approx. 51g/1.8oz Trigger mode:  1 low pulse trigger (falling edge trigger) 2 low level trigger (rising edge trigger)     Timer:  T1: Forward timer T2: Reverse timer T3: Stop timer Time unit : 0.1 second, 1 second, 1 minute     Relay action:  Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing. Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing.. Motor stop   : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.     Factory settings:  Press the "++" and "--" buttons simultaneously for 5 seconds.     Energy-saving mode:  Press and hold the "OK" button for 5 seconds to enter the "Energy-saving mode". Press and hold the "OK" button again for 5 seconds to exit the "Energy-saving mode". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.   Function mode:  F-01 After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)    F-02 This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.    F-11(Trigger  reversible 1) Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1). Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2). When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-12(Trigger  reversible 2) Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid). Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid). When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-21 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same tim
  • Fruugo ID: 415389671-876936588
  • EAN: 8461339294249

배송 및 반품

24시간 이내에 발송됨

  • STANDARD: ₩8,049 - 배달 사이 수 22 10월 2025–금 31 10월 2025

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659