설명
_x000D_
2X Driver Board P-134 VU Meter Drive Board VU Meter Audio Backlight Analog Digital Power Meter
_x000D_
_x000D_
_x000D_
_x000D_
VU Meter Features:Standard test conditions temperature: 20 Celsius, humidity 70% . Can also be tested under normal temperature and humidity.The influenza degree pointer at the zero scale to the maximum scale sensitivity of 1000 uA 10% (full scale position);Internal impedance :800 ohm 10%;Insulation impedance meter outside the box plus the electrical circuit with 500V DC plus 50M ohm meter shell
Electrical insulation of the circuit impedance is 500V DC voltage test of the insulation value. Pointer to overlap with the zero-scale tolerance of 1mm balanced meter using a standard position and tilt 90 degrees to allow the error range of 1mm;Pointer to mount the current instant plus three times the full scale current, and slowly reduced to the the electric influenza degree 1/2 reading,
The pointer will return to the scale plate within 1/3 scale friction meter coupled with the current, and slowly increase or decrease to a certain value, indicating the point of error range of 1mm,Brake instantly plus scale plate 2/3 of the current value of the pointer indicates the location of the time required for a second or less.
VU Meter Special Test:Tests on each interval of five seconds to ten times the full scale current input overload, the action is repeated nine times for each time of 0.5 seconds .After this test, 7-14 to maintain normal.Vibration test meter packaged in the vibration plate 1,000 times per minute, up and down 4mm shock In each direction for 10 minutes.
After this test 7-14 to maintain normal impact test meter packaged 30-cm height of fall in 3cm thick wooden board, XYZ three-direction test.After this test, 7-14 to maintain normal reliability test the current input of 100,000 calibration points within the limits of current sense is still the standard environmental impact test temperature of 50 Celsius, humidity 85%, for 100 hours, after this test 7-14 to maintain normal.
Terminal pull test: terminals must withstand one kilogram tension, sustained 60 seconds will not be affected.
VU Meter Others:
Using the temperature limits: -10 Celsius to +60 Celsius RH 35 to 85%
Storage temperature limits: -20 Celsius to +60 Celsius RH 35 to 85%
Do not use the meter in direct sunlight, and PUT the meter in the box to avoid foreign matter into the meter internal.
Soldering Condition terminal about 3 mm placed in the temperature of 230 Celsius tin plate, placed 3.5 seconds.
After this test, 7-14 to maintain normal,
Hand-held soldering gun to solder temperature 350 Celsius, the terminal contact for 3.5 seconds, the terminal front-end of about 3mm contact with the solder gun.
After this test, 7-14 to maintain normal,
Anti-static test in the same direction three times, to characterize the difference between the pointer in the length of the scale in a transparent cover surface to dry nylon 1/3 back to the zero position.
Bulb size: 4 blue LED backlighting, parallel to the PCB (3.0-3.2V 80mA)VU Meter
The direction of the pointer swing: left to right
Pointer length: 70 1 mm from the center axis to the needle end
Pointer width: 0.45 0.05 mm
Colour:Black + Blue
Material:Zinc cupronickel
Size:13.4x9.5x4.5cm
Package Contents:
2 x VU level meter
Only the above package content, other products are not included.
Note: Light shooting and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
_x000D_
-
Fruugo ID:
333785556-735802363
-
EAN:
7255003334550
제품 안전 정보
아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.
以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。
제품 안전 라벨
안전 경고:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
재료:
Octinoxate 7.483%
제조업체 부품 번호:
ZZ000372
모델 번호:
ZZ713580
일련번호:
ZZ101259
배치 번호:
ZJ520504