12V Digital Temperature Controller with Dual Probe, LED Display, Heat-Cool Control

₩73,390
무료 배송

12V Digital Temperature Controller with Dual Probe, LED Display, Heat-Cool Control

판매자::

₩73,390

할인 ₩36,600 (33%)

권장소매가

₩109,990
재고 있음
무료 배송

14일 반품 정책

결제 방법:

  • 브랜드: Unbranded

설명

12V Digital Temperature Controller with Dual Probe, LED Display, Heat-Cool Control

High-precision intelligent temperature controller with digital display designed for hot water circulation, return-water system control, and similar applications. Key benefits - Precise dual-sensor control that improves thermal efficiency by switching heating or cooling cycles based on the measured temperature difference between a high-temperature sensor and a low-temperature sensor. - Real-time digital tube display shows both high and low temperature values for immediate monitoring. - Isolated control power prevents voltage fluctuations on the control board when large power devices start or stop, improving system stability. - Automatic sensor detection and permanent parameter memory preserve settings and operating state after power loss. - Simple wiring and relay output make it easy to control pumps and other devices. Core functions and operation - Two operating modes - One-way mode: Relay A activates when high-temperature sensor value minus low-temperature sensor value exceeds the preset temperature difference. Relay A opens when the difference falls below the preset return difference. If low-temperature sensor value is greater than high-temperature sensor value, the relay remains inactive. - Two-way mode: Relay A activates when the absolute difference between the two sensor temperatures exceeds the preset temperature difference. Relay A opens when the difference falls below the preset return difference. - Hysteresis control: The device uses a preset temperature difference and a separate smaller return difference to avoid rapid on/off switching and to ensure stable cycling. - Example settings - Solar hot water circulation: Set temperature difference to 5.0 C and return difference to 0.5 C. When high-temp minus low-temp exceeds 5.0 C the relay drives the circulation pump; when the difference drops to 4.5 C the relay switches off. - Air convection cycle: Set temperature difference to 3.0 C and return difference to 0.3 C. When the difference exceeds 3.0 C the relay activates the fan or pump; when the difference drops to 2.7 C the relay deactivates. Technical parameters and notes - Control is based on the temperature difference between two measurement points (high temperature and low temperature) to operate water pumps or other outputs. - The device evaluates temperature difference as high sensor reading minus low sensor reading. - Automatic detection of connected sensors. If no sensor is present or only one probe is connected the alarm indicator will display 0000. - Non-volatile storage preserves the last parameter set and operating state after power off. - The product was originally designed with two relays. To avoid wiring errors the current version is supplied with a single relay and one white connector. Buyers should use the single-relay wiring provided. Connection and wiring - Power input: blue 2-pin connector. Plus is the positive terminal, minus is the negative terminal. A DC power supply can be connected directly. - Power wiring may be routed through the tubular connector; the flat right terminal can be used for actuation. - Output: relay output used to switch pumps and related equipment. Suitable applications - Solar hot water circulation systems where pump activation is required only when the collector is sufficiently hotter than the storage tank. - Return-water control and pump cycling in residential or light commercial hot water circulation systems. - Air convection or fan control based on temperature differences between two locations. Compatibility and performance - Designed for systems that require dual-sensor temperature difference control and relay switching for pumps or fans. - Provides stable cycling control with user-adjustable temperature difference and return difference settings to minimize unnecessary switching and improve heating or cooling efficiency. This controller offers clear dual-sensor monitoring, reliable hysteresis control, isolated control power for stable operation, and simple relay output wiring for pump and fan control.
  • Fruugo ID: 512149631-1046341897
  • EAN: 6258520180885

배달

7일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 금 11 9월 2026–금 02 10월 2026 - 무료

중국에서 발송.

보고

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다.

전체 반품 정책 보기

製品コンプライアンスの詳細

以下に概説されているこの製品に固有のコンプライアンス情報を参照してください。

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제조사:
다음 정보는 Fruugo에서 판매되는 관련 상품의 제조사 연락처입니다.

  • Guizhou Jingxing Media Co., Ltd.
  • Guizhou Jingxing Media Co., Ltd.
  • Binhe East Road and Wangcheng Road
  • Intersection, Botai Peninsula Shuiwan 1402
  • Hongshan Street, Qixingguan District
  • Bijie
  • CN
  • 551700
  • [email protected]
  • 8618200255082

EU 내 책임자:
다음 정보는 EU 내 책임자 연락처입니다. 책임자는 유럽 연합에서 판매되는 관련 상품에 대한 준수 의무에 책임을 지는 EU에 기반을 둔 지정 경제 주체를 말합니다.

  • GLOBEREX SPAIN SOLUCIONES SLU
  • GLOBEREX SPAIN SOLUCIONES SLU
  • CALLE TORCAL, 2,5 D
  • Madrid
  • ES
  • 28041
  • [email protected]
  • 34621668802