1/2 Water /Paddle Flow Switch Thread Connection SPDT Contacts Red(Partial Stainless Steel Type)

₩50,490
무료 배송

1/2 Water /Paddle Flow Switch Thread Connection SPDT Contacts Red(Partial Stainless Steel Type)

  • 브랜드: Unbranded

1/2 Water /Paddle Flow Switch Thread Connection SPDT Contacts Red(Partial Stainless Steel Type)

  • 브랜드: Unbranded
희망소매가격: ₩65,690
가격: ₩50,490
절약 금액: ₩15,200 (23%)
판매자::
₩50,490
무료 배송

재고 있음

다음의 결제 방식을 사용하실 수 있습니다

설명

Features:100% brand new and high qualityThe product is used to measure the dynamic state of the liquid flowing through the pipeline, such as: water, ethylene, ethylene glycol and other liquids that have no corrosive effect on copperApplication: water treatment system, central air conditioning, water cooling unit, fire protection system and other fields.Adopts premium material, with strong temperature adaptability of 0~ 120, and can withstand high pressure of 1.0Mpa.The flow control value is adjustable and the action repetition point is stable.Specification:Material:brass and stainless steel(body), stainless steel( Leaf blade), plastic (shell)Interface dimensions: 1/2"(HFS-15)Control mode: blade typeMax. working pressure: 1.0MpaAmbient temperature: 0C~60Liquid temperature: -10~100(non-freezing)Micro switch: single pole double throw (SPDT)Contact life: 100, 000 cyclesElectrical parameters of micro - switch: 220VAC, 15AWeight: Approx.407g/14.4ozPackage list:1 x flow switch1 x Chinese and English operation manual3 x paddleInstallation and adjustment:1. Open the flow switch housing;2. The switch has been set at the minimum flow value when leaving the factory. Increase the flow setting value and turn the adjusting screw counterclockwise;3. Press the target to check whether the micro switch can work normally. Excessive clockwise rotation of the adjustment screw may lead to the failure of the flow switch;4. After the installation, please press the lever of flow switch several times to check. Once it is found that there is no "click" sound when the lever is restored, rotate counterclockwiseAdjust the screws until there is a "click" sound;5. The adjustment screw of lacquer seal is only for factory to adjust the state of flow switch. Please do not change or adjust it6. Observe three working cycles, make sure that the switch and the system connected with it are in normal operation, and cover the switch shell in time.Matters needing attention:1. Please check the flow switch carefully before installation. The package should be complete and the appearance should be free from damage and deformation. If you have any questions, please contact the manufacturer:2. The flow switch can be installed in the horizontal pipe or the vertical pipe with the upward direction of liquid flow, but it cannot be installed in the pipe with the downward direction of liquid flow. Gravity should be considered when installing in piping above the flow direction of the fluid3. The flow switch must be installed on the straight pipe of the section, both sides of which are short of the straight stroke of 5 letter pipe diameter. At the same time, it should be noted that the direction of liquid flow in the pipe must be consistent with the direction of arrow on the switch shell.4. The HFS flow switch shall not be used in pipelines where the liquid temperature drops below the freezing point of the liquid. 5. The HFS flow switch cannot be hit by water. If there is a quick closing valve in the downstream of the flow switch, the throttle must be used.6. When installing wiring, please pay attention to the following matters:* it is absolutely forbidden to impact the wrench on the switch bottom plate, resulting in deformation failure of the flow switch;* to avoid electric shock and damage to the equipment, cut off the power supply when wiring or debugging;* when wiring, it is absolutely forbidden to adjust any screws other than micro switch terminals and grounding screws. It should be noted that the micro switch wiring cannot be usedIf the force is too strong, it will easily cause the position displacement of the micro switch itself and lead to the failure of the flow switch.* special grounding screws must be used for wiring, and installation screws cannot be removed at will, otherwise the controller will be deformed and invalid;* the blade of the flow switch cannot contact with the inner wall of the pipe and other throttles in the pipe, otherwise the switch cannot be reset normally.
  • 브랜드: Unbranded
  • 카테고리: 센서
  • Fruugo ID: 426049127-894819509
  • EAN: 7313854265178

제품 안전 정보

아래에 설명된 이 제품과 관련된 제품 안전 정보를 참조하십시오.

以下の情報は、この製品を販売する独立したサードパーティ小売業者によって提供されています。

제품 안전 라벨

CE Mark
안전 경고: Warning: Please read the product instructions carefully before use to ensure correct use.
일련번호: 7313854265178

배송 및 반품

2일 이내에 발송됨

  • STANDARD: 무료 - 배달 사이 화 09 12월 2025–화 16 12월 2025 - 무료

중국에서 발송.

당사는 귀하께서 주문하신 제품이 주문 명세에 따라 빠짐없이 배송되도록 온 힘을 기울이고 있습니다. 다만, 주문하신 것과 다른 상품이 배송되거나 빠진 상품이 있는 경우, 또는 주문 내용에 만족할 수 없는 다른 이유가 있는 경우에는 주문 전체나 주문에 포함된 일부 제품을 반품하시고 해당 상품에 대해 전액 환불받으실 수 있습니다. 전체 반품 정책 보기